Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
laser_module_30603500u [2020/06/16 18:05] dav |
laser_module_30603500u [2022/03/18 11:53] dav |
||
---|---|---|---|
Line 1: | Line 1: | ||
- | {{https://nejetool.oss-us-west-1.aliyuncs.com/wiki/module_7w/size1.png}} | + | Compatible with master 2/2s 3, NEJE 2S/3 plus, NEJE 3 Pro, NEJE 2S/3 Max machines |
- | {{http://nejetool.oss-us-west-1.aliyuncs.com/wiki/module_3500U/001.jpg?250x250}} | + | ===== Interface ===== |
- | {{http://nejetool.oss-us-west-1.aliyuncs.com/wiki/module_3500U/002.jpg?250x250}} | + | |
- | {{http://nejetool.oss-us-west-1.aliyuncs.com/wiki/module_3500U/004.jpg?250x250}} | + | |
- | {{http://nejetool.oss-us-west-1.aliyuncs.com/wiki/module_3500U/005.jpg?250x250}} | + | |
- | {{http://nejetool.oss-us-west-1.aliyuncs.com/wiki/module_3500U/006.jpg?250x250}} | + | |
- | **[[http://www.neje.club/download/20200612/How_to_get_laser_temperature.pdf|How_to_get_laser_temperature.pdf]]** | + | {{https://nejetool.oss-us-west-1.aliyuncs.com/wiki/NEJE_3_Max/A40640_interface.png?300x300}} |
+ | |||
+ | 12V: Power positive . | ||
+ | |||
+ | GND: Power ground or power negative. | ||
+ | |||
+ | TTL/PWM: TTL = PWM, input 3.3V~12V to turn on laser module, conect to GND to turn off laser module. | ||
+ | |||
+ | Temperature: do not connect, please ignore. | ||
+ | |||
+ | Connect 12V and GND pin to 12V power, ensure the power adapter is sufficient, 5A is recommended. | ||
+ | |||
+ | Connect TTL/PWM pin to your control board PWM output pin. | ||
- | Main applications: grayscale engraving, drawing, simple depth engraving, simple cutting, etc. | ||
- | Interface specification: 4pin PH2.0 (red: 12V, black: GND, yellow: PWM, green: temperature signal) | ||
- | Wavelength: 405nm | ||
- | Radiator size: 30*60mm | ||
- | Material: copper + aluminum | ||
- | Weight: 121g | ||
- | Drive position: built-in | ||
- | Is the power adjustable: PWM can be adjusted | ||
- | Drive protection: surge protection, overvoltage protection | ||
- | Input power: approx. 12V280ma (including fan power) | ||
- | Line length: 300mm | ||
- | Control line installation method: split type | ||
- | Fan size: 30*10mm | ||
- | Fan speed: 10,000 rpm | ||
- | Controllable temperature: less than 60 degrees Celsius | ||
- | Focus range: 5-50mm | ||
- | Best focal length: 10mm from the light exit | ||
- | Safety Warning: Please apply this module under the premise of safety protection! | ||
- | Recommended application machine: NEJE Master | ||
- | packing list: | ||
- | 1 x module | ||
- | 2 x screw | ||
- | 2 x gasket |